OpportunitiesConversions from Electric tank to Tankless, Green Building Designs: Res., Comm. and Industrial.
Manufactured and Mobile Homes comprise 25% of Affordable housing.
HOUSING AUTHORITIES, State Directors for Funding, Single, Multi, ALF, Nursing Homes, Dorms and Institutional, Prisons, Residential Housing, New, Retrofit and Remodels (NARI).
If you or your company are licensed and would like to resell and install our products, please contact us today at
Super Green Nano Tech Tankless InformationHow Super Green Nano Tech Tankless Works?
Super Green Nano Tech Tankless Product Information

Unversity of South Florida: Independent Research on Super Green Nano Tech Tankless Hot Water Generator
Green Products and Services Directory:
- Conservation Departments
- Energy Conservation Products
- Energy Conservation Services
- Energy Management Systems
- Environmental Conservation
- Environmental Consultants
- Environmental Control Services
- Environmental Engineers
- Environmental Programs
- Environmental Services
- Green Company Miscellaneous
- Oil Recycling
- Recycling Centers
- Recycling Equipment
- Solar Energy
- Solar Energy Equipment
- Waste Reduction Services
![]() | ![]() |
Eco-4 Project - Anti-Microbial Effect of UV/Far InfraRed Water Treatment System on E. coli K-12
Materials:
UV/FIR Water Treatment System4 gallons/min (15.14 L/min) Hot Water Generator (HWG) – modified to use 120V
15 gallon/min (56.78L/min) UV Sterilizer
20 L/min Hot Water Boost Pump
Intake and Connections - 5/8" ID Clear Vinyl Tubing
Discharge - 0.375" ID Silicone Tubing
Set-up:
Supply tank, boost pump, UV Sterilizer, and Hot Water Generator connected by 5/8" ID Clear Vinyl Tubing. Discharge tubing connecting HWG to discharge tank is 0.375" ID silicone tubing.Flow Rate: 5238 mL/min
Transit time (Supply intake to discharge): 30 sec
Temperature increase: 12 oF (6.6°C)
Temperature Range: 71oF (21.7°C) to 83°F (28.3°C)
Methods:
E coli K-12 was grown in Tryptic Soy Broth overnight at 35°C resulting in an OD600 of 0.5 to 0.6 and a final concentration of approximately 3.5x 109 CFU/ mL.
Eight to 80 mL of overnight bacterial culture were added to 40 Liters of de-ionized water in the supply tank with constant stirring.
Pump primed and placed into supply tank.
Assay conducted as follows:
| T=0 min | Start | Start Pump |
| T=1 min | Control sample | Collect -UV/-FIR sample, start UV |
| T=2 min | UV only sample | Collect +UV/-FIR sample, start HWG |
| T=3 min | UV + FIR sample | Collect +UV/+FIR sample, turn off UV |
| T=6 min | FIR only sample | Collect -UV/+FIR sample, turn off HWG |
Water Quality Testing
Water was analyzed by standard EPA water testing methods, SM 9222 B - Membrane Filter Method for the Enumeration of Total Coliforms.In brief, serial dilutions of each sample were filtered through 0.22 micron filters and the filters were incubated on m-Endo agar, overnight at 35 °C. Plates from each dilution were counted and the mean CFU/mL determined.
Results:
| Colony Forming Units per Milliliter (CFU/mL) |
|
|
Control |
+UV only |
+UV/+FIR |
+FIR only |
|
Mean |
6.29x104 |
1.08 |
0.206 |
2.88x104 |
|
Std Dev |
1.57x103 |
0.935 |
0.185 |
1.08x104 |
This assay was repeated three times to produce the date within this report. All three results were similar.

These results indicate that both the UV sterilizer and the UV/FIR combination treatment consistently result in a significant log reduction of viable CFUs. The UV treatment alone resulted in a 4.5 log reduction from control levels and the combination UV+FIR had more than a five log reduction. The effect of the FIR alone is much less than that of the UV however it may be of significance. Looking at the results more closely in the 104 range does show a consistent, albeit small, 0.2 to 0.3 log reduction in CFUs from the FIR alone.

This taken in conjunction with one log increase in anti-microbial effect observed when the UV and FIR are used in conjunction leads me to believe that the FIR may well have an independent anti-microbial effect. Whether this is due strictly due to the increase in temperature is unknown at this time, however since the maximum water temperature measured during these assays was 83°F (28.3°C) it is possible that the effect is more than simply a 12 oF (6.6°C) rise in water temperature. To be certain a direct comparison of HWG vs. Standard water heating would need to be tested.
Product: Tankless Hot Water Generator, ElectricComplies with UL 499